Operational settings for Auto Drain timers.

Auto Drain model 2000 Solenoid Auto Drain for Condensate Removal model 3000

Model 2000 (factory set 1 sec on - 1 min off)

On time (seconds)

  • Press and hold the ON arrow until it begins to flash
  • Increase on time by pressing the right arrow
  • Decrease the on time by pressing the left arrow
  • Once the setting is reached press TEST/ENTER

Off time (minutes)

  • Press and hold the OFF arrow until it begins to flash
  • Increase off time by pressing the right arrow
  • Decrease the off time by pressing the left arrow
  • Once the setting is reached press TEST/ENTER

Test Funtion

  • Press and release TEST/ENTER
    • Solenoid will energise for the ON setting

Model 3000 (reverse) (factory set 1 sec off - 1 min on)

On time (minutes)

  • Press MODE until the display reads OPEN
  • Press MODE again and digits 5 and 6 begin to flash
  • Press ADD and DEC together and digits 3 and 4 will flash
  • Press ADD to incease or press DEC to decrease
  • Press MODE to keep the setting
  • At any time press RESET to return

Off time (seconds)

  • Press MODE until the display reads CLOSE
  • Press MODE again and digits 5 and 6 begin to flash
  • Press ADD to incease or press DEC to decrease
  • Press MODE to keep the setting
  • At any time press RESET to return

Off-On Mode

  • Press MODE until OFF-ON begins to flash
  • Press ADD until OFF-ON flashes in display (setting for reverse operation - solenoid is OFF to start)
  • Press MODE to keep the setting
  • At any time press RESET to return

Test Funtion

  • Press and release RESET to re-start the cycle